HCS121VXY Heating & Cooling Stage
- 
	
Microscopy and spectroscopy stage
 - 
	
-190°C ~ 100°C with liquid nitrogen cooling option
 - 
	
28 mm × 30 mm sample area
 - 
	
XY sample positioning
 - 
	
Sealed chamber with vacuum capability
 
Thermal Features
| 
			 Temperature Control  | 
			
			 mK2000 with programmable precision switching PID method  | 
		
|---|---|
| 
			 Thermal Block  | 
			
			 Silver  | 
		
| 
			 Sample Thermal Cover  | 
			
			 Removable Inner sample cover with additional window  | 
		
| 
			 Temperature Minimum  | 
			
			 -190°C (with optional liquid N2 cooling)  | 
		
| 
			 Temperature Maximum  | 
			
			 100°C  | 
		
| 
			 Temperature Sensor  | 
			
			 100 Ω Platinum RTD  | 
		
| 
			 Maximum Heating Rate  | 
			
			 +150°C per minute at 37°C  | 
		
| 
			 Maximum Cooling Rate  | 
			
			 -60°C per minute at 100°C  | 
		
| 
			 Minimum Heating and Cooling Rate  | 
			
			 ±0.01°C per minute  | 
		
| 
			 Temperature Resolution  | 
			
			 0.01°C  | 
		
| 
			 Temperature Stability  | 
			
			 ±0.05°C (above 25°C), ±0.1°C (below 25°C)  | 
		
| 
			 Power supply  | 
			
			 Universal power input  | 
		
| 
			 Software  | 
			
			 Windows software to record and export temperature-time data  | 
		
Optical Features
| 
			 Temperature Control  | 
			
			 mK2000 with programmable precision switching PID method  | 
		
|---|---|
| 
			 Thermal Block  | 
			
			 Silver  | 
		
| 
			 Sample Thermal Cover  | 
			
			 Removable Inner sample cover with additional window  | 
		
| 
			 Temperature Minimum  | 
			
			 -190°C (with optional liquid N2 cooling)  | 
		
| 
			 Temperature Maximum  | 
			
			 100°C  | 
		
| 
			 Temperature Sensor  | 
			
			 100 Ω Platinum RTD  | 
		
| 
			 Maximum Heating Rate  | 
			
			 +150°C per minute at 37°C  | 
		
| 
			 Maximum Cooling Rate  | 
			
			 -60°C per minute at 100°C  | 
		
| 
			 Minimum Heating and Cooling Rate  | 
			
			 ±0.01°C per minute  | 
		
| 
			 Temperature Resolution  | 
			
			 0.01°C  | 
		
| 
			 Temperature Stability  | 
			
			 ±0.05°C (>25°C), ±0.1°C (<25°C)  | 
		
| 
			 Power supply  | 
			
			 Universal power input  | 
		
| 
			 Software  | 
			
			 Windows software to record and export temperature-time data  | 
		
Structural Features
| 
			 Sample Area  | 
			
			 28 mm x 30 mm  | 
		
|---|---|
| 
			 Chamber Height  | 
			
			 2.8 mm  | 
		
| 
			 Sample Access  | 
			
			 Side-loading outer cover for quick sample access without refocusing instruments  | 
		
| 
			 Sample Positioning  | 
			
			 10 mm fine travel with Vernier XY dials for remote manipulation in sealed chambers  | 
		
| 
			 Atmosphere Control  | 
			
			 Sealed chamber with vacuum capability to control humidity, condensation, and oxidation  | 
		
| 
			 Frame Cooling  | 
			
			 Integrated frame cooling via hose barb ports with optional chiller system  | 
		
| 
			 Mounting  | 
			
			 Horizontal and vertical mounting capability  | 
		
| 
			 Frame Dimensions  | 
			
			 153mm x 90 mm x 22 mm  | 
		
| 
			 Weight  | 
			
			 1350 g light-weight aluminum body  | 
		