Isothermal Calorimeter |
I-Cal Isothermal Calorimeters |
I-Cal Ultra |
F-Cal 8000 |
Type of calorimeter
|
Isothermal
|
Isothermal
|
Isothermal
|
Semi-adiabatic
|
Standards
|
ASTM C1679 - isothermal calorimetry, ASTM C1702 - heat of hydration,
ASTM C563 - sulfate optimization, ASTM C1897 - pozzolanic reactivity, EN 196-11 |
ASTM C1753 (Semi-adiabatic calorimetry)
|
||
Number of test channels
|
1 - 2 (flexible)
|
I-Cal 2000 HPC: 2 cell
|
Up to 8 (flexible, individual plug-and play calorimeter)
|
8 channels
|
or
|
I-Cal 4000 HPC: 4 cell
|
|||
1 to 8 (flexible)
|
I-Cal 8000 HPC: 8 cell
|
|||
Vial size
|
450 ml vials or 20 ml vials
|
125 ml
|
20 ml
|
0.6 l
|
Sample size
|
450 ml vials or 20 ml vials
|
Up to 125ml (340g mortar)
|
20 ml
|
Up to 1.9 kg
|
Sample vials reusable
|
|
✓
|
|
-
|
Cement paste
|
✓
|
✓
|
✓
|
✓
|
Mortar
|
✓
|
✓
|
|
✓
|
Concrete
|
✓
|
|
|
✓
|
Internal (in-situ) mixing capability (optional)
|
✓
|
✓
|
✓
|
|
High effciency mixing
|
✓
|
✓
|
✓
|
|
Operating Temperature range
|
2 °C to 90 °C
|
5 °C to 70 °C
|
4 °C to 90 °C
|
4 °C to 90 °C
|
Thermostat Type
|
Air
|
Air
|
Air
|
Air
|
Temperature Stability
|
± 0.005 °C
|
± 0.02 °C
|
± 0.01 °C
|
± 0.005 °C
|
Limit of Detection
|
2 μW
|
5 μW
|
2 μW
|
2 μW
|
Precision
|
|
I-Cal 2000 HPC: ± 60 μW
|
± 2 μW
|
± 2 μW
|
± 2 μW
|
I-Cal 4000 HPC: ± 100 μW
|
|||
|
I-Cal 8000 HPC: ± 2 μW
|
|||
Short term noise
|
± 2 μW
|
± 10 μW
|
± 2 μW
|
|
Operating Voltage
|
110-240 VAC – 50/60Hz
|
110-240 VAC – 50/60Hz
|
110-240 VAC – 50/60Hz
|
3.6-Volt built-in Lithium battery
|
Battery operated
|
|
|
Operate and store data logged for up to 7 days
|
|
Battery life: 8 years
|
||||
Accuracy : ± 0.2% at 25 °C
|
||||
Response Time: < 2 min. to 90%
|
||||
Resolution : 0.0018 %
|
||||
Sampling rate: 1 min
|
||||
Software modules for data analysis
|
Reporting and Export into Excel, Matlab, etc., Set time estimation, Compressive Strength estination, Sulfate Optimization, Heat of Hydration testing, Cement plant Process Control, Activation Energy
|
Reporting and Export, Set time estimation, Compressive Strength estination
|
||
Software Compatibility
|
CalCommander on Windows 7/ 10 or later
|
CalCommander on Windows 7/ 10 or later
|
CalCommander on Windows 7/ 10 or later
|
CalCommander on Windows 7/ 10 or later
|
Max. recommended test duration
|
28 days
|
28 days
|
28 days
|
28 days (36 hours for testing in field conditions) (Battery operated and data logged for up to 7 days)
|
Baseline (24 hours) Drift
|
|
< 20 μW (I-Cal 2000 HPC)
|
Drift <5 μW
|
Drift <5 μW
|
Drift < 5 μW
|
< 60 μW (I-Cal 4000 HPC)
|
|||
|
< 80 μW (I-Cal 8000 HPC)
|
|||
Baseline (24 hours) Deviation
|
|
< ± 25 μW (I-Cal 2000 HPC)
|
|
Deviation < ± 1 μW
|
Deviation < ± 1 μW
|
< ± 50 μW (I-Cal 4000 HPC)
|
Deviation < ± 1 μW
|
||
|
< ± 50 μW (I-Cal 8000 HPC)
|
|
||
|
|
Error < ± 10 μW
|
||
Dimension (cm)
|
43 cm x 33 cm x 48 cm
|
43 x 33 x 48 (I-Cal 2000 HPC)
55 x 42 x 56 (I-Cal 4000 / 8000 HPC)
|
50 x 40 x 108, cm
|
62.5 x 62.5 x 35, cm
|
Weight (kg)
|
34 kg |
26 kg (I-Cal 2000 HPC)
47 kg (I-Cal 4000 / 8000 HPC)
|
34 kg
|
12.7 kg
|
Feature and application
|
I-Cal Flex의 구성은 균질 식품에 대해 20ml 용량의 최대 8 개의 시료 셀 또는 토양, 과일, 육류 및 미네랄, 곤충, 농작물 및 씨앗, 슬러지, 시멘트 또는 콘크리트 등과 같이 많은 시료량에 적합한 불균일한 시료에 적합한 바이알과 함께 450ml 용량의 최대 2 개의 시료 셀 중에서 선택할 수 있습니다. I-Cal Flex의 등온 온도는 2°C까지 낮게 설정할 수 있으며 동급 최고의 정밀도와 baseline stability을 제공합니다. |
I-Cal HPC는 새로운 시멘트 제품 또는 혼합물의 연구 개발에서 시멘트 플랜트의 공정 및 품질 관리에 이르기까지 시멘트 및 콘크리트 전문가의 요구 사항을 충족하도록 설계된 등온 열량계입니다. 이 고성능 열량계 (HPC)는 ASTM C1702 (수화열 테스트) 및 ASTM C1679 (등온 열량계)를 준수합니다. |
I-Cal Ultra는 1 ~ 8 개의 샘플 셀을 수용할 수 있으며 시멘트 및 포졸란 재료 분야에서 소량 샘플을 테스트하도록 설계되었습니다. I-Cal Ultra는 뛰어난 감도, 정밀도 및 온도 제어 기능을 제공합니다. ASTM C1679 및 ASTM C1702 표준을 완벽하게 준수하는 것 외에도 성능 수준을 통해 최대 몇 개월의 매우 장기적인 테스트를 포함하여 훨씬 더 고급 연구가 가능합니다. |
F-Cal semi-adiabatic calorimeter는 concrete flatwork의 조건을 시뮬레이션하도록 설계되었습니다. 휴대성이 있어 콘크리트 플랜트, 현장 작업 또는 모바일 실험실에서 믹스 디자인, 문제 해결 또는 품질 관리에 이상적입니다. F-Cal은 ASTM C1753을 준수합니다.
|
Applications: | A vast selection from the Materials and LIfe Sciences, including Food Science, Microbiology, Agricultural Science, Polymers, Soil Science, Marine Life, Environmental Science, etc. | Cement and Concrete Research and Quality Control, Admixture development, Geopolymers, "green" Cements | Advanced Cement Research, Admixture development, Geopolymers, "green" Cements | Concrete mix design, Raw material selection, Troubleshooting, all uses as a Field equipment |
More Details |
Isothermal Calorimeter |
I-Cal Isothermal Calorimeters I-Cal 2000 HPC I-Cal 4000 HPC I-Cal 8000 HPC |
Isothermal Calorimeter |
F-Cal 8000 Portable semi-adiabatic calorimeters for lab and field |