Thermal Properties Analyzer

Thermal conductivity (Lambda), Ash fusion, Thermal screening

Microscopic Hot/Cold Stage, Wafer chuck, Thermal plate, Thermal probe station

HP1200G Compact Thermal Plate


  • High temperature microscopy & spectroscopy plate
  • 30°C ~ 1200°C
  • Φ12 mm sample area
  • Gas-tight chamber *Vacuum-tight model available (HP1200V)

 

DESCRIPTION

Instec의 HP1200 Hot Gas-Tight 스테이지는 샘플을 1200 °C까지 가열할 수 있으며 세라믹, 야금, 지질학 및 고온 재료 연구에 이상적입니다. Electrical feedthrough 및 맞춤형 샘플 영역 (sample area)이 가능합니다. HP1200G의 gas-tight 샘플 챔버는 고온에서 샘플 산화를 방지하는 데 도움이 됩니다.

 

THERMAL FEATURES

Temperature Control

mK2000 with programmable precision switching PID method

Thermal Block

Ceramic

Sample Thermal Cover

Removable Inner sample cover with additional window

Temperature Minimum

30°C (active cooling not available)

Temperature Maximum

1200°C

Temperature Sensor

S Type Thermocouple

Maximum Heating Rate

+200°C per minute at 100°C

Minimum Heating and Cooling Rate

±0.5°C per minute

Temperature Resolution

0.1°C

Temperature Stability

±1°C 

Power supply

Universal power input

Software

Windows compatible software to record and export temperature-time data; remotely control system via VCP connection (Virtual Comm Port)

 

OPTICAL FEATURES

Optical access

Reflection capability

Optical windows

Removable and exchangeable windows permit full-spectrum transparency

Minimum Objective Working Distance

9.0 mm

Top Aperture

38 mm diameter

Top Viewing Angle

±24.5° from normal

 

STRUCTURAL FEATURES

Sample Area

Φ12 mm x 5 mm

Atmosphere Control

Gas purging capability to control humidity, condensation, and oxidation

Frame Cooling

Integrated frame cooling with optional chiller system

Window and objective protection

Cooling by purge air

Mounting

Horizontal and vertical mounting

Frame Dimensions

200 mm x 120 mm x 30 mm

Weight

1350 g 

HP1200G Compact Thermal Plate

Instec's HP1200 Hot Gas-Tight stage can heat samples to 1200°C and are ideal for the study of ceramics, metallurgy, geology and high temperature materials. Electrical feedthroughs and custom sample areas are also available. The HP1200G's gas-tight sample chamber helps to prevent sample oxidation at high temperatures.


 

Instec, Inc. USA
share
Wafer Chuck HCC ROUND WAFER CHUCKS Round thermal wafer chucks Designed for wafer handling Modern electrical probing and testing Multi
댓글 0
11,577
Compact Thermal Plate HP1200G Compact Thermal Plate High temperature microscopy & spectroscopy plate 30°C ~ 1200°C Φ12 mm sample area Gas-tight cha
댓글 0
1,239
Compact Thermal Plate HP1500G Compact Thermal Plate High temperature microscopy & spectroscopy stage Rotating sample observation window 30°C ~ 1500
댓글 0
1,188
Compact Thermal Plate HCP421V Compact Thermal Plate Compact reflection stage for microscopy & spectroscopy -190°C ~ 400°C with liquid nitrogen cool
댓글 0
14,623
« 1 2 3 4 5 6 7 8 »
« 5 / 8 »