HCS621GXY Thermoelectric Stages
- 
	
Optical microscopy and spectroscopy
 - 
	
-190°C - 600°C with liquid nitrogen cooling option
 - 
	
28 mm × 30 mm sample area
 - 
	
XY sample positioning
 - 
	
Sealed chamber with gas purging capability
 
Description
Instec의 HCS621GXY gas-tight stage는 넓은 온도 범위와 분위기 제어가 중요한 애플리케이션을 위해 설계되었습니다. 이 스테이지에는 silver heating 및 cooling block이 있어 온도 균일성(temperature uniformity)이 뛰어납니다. 응축 (condensation) 또는 산화(oxidation)를 방지하도록 가스 퍼지를 위한 씰드 챔버를 제공합니다.
HCS621GXY 스테이지에는 샘플 체결 및 프로빙이 가능하도록 최대 8 개의 elecric feedthrough 옵션을 추가할 수 있습니다.
Thermal Features
| 
			 Temperature Control  | 
			
			 mK2000 with programmable precision switching PID method  | 
		
|---|---|
| 
			 Thermal Block  | 
			
			 Silver for superior thermal uniformity  | 
		
| 
			 Temperature Minimum  | 
			
			 -190°C (with optional liquid N2 cooling)  | 
		
| 
			 Temperature Maximum  | 
			
			 600°C  | 
		
| 
			 Temperature Sensor  | 
			
			 100 Ω Platinum RTD  | 
		
| 
			 Maximum Heating Rate  | 
			
			 +150°C per minute at 100°C  | 
		
| 
			 Maximum Cooling Rate  | 
			
			 -50°C per minute at 100°C  | 
		
| 
			 Minimum Heating and Cooling Rate  | 
			
			 ±0.01°C per minute  | 
		
| 
			 Temperature Resolution  | 
			
			 0.01°C  | 
		
| 
			 Temperature Stability  | 
			
			 ±0.05°C (above 25°C), ±0.1°C (below 25°C)  | 
		
| 
			 Power Supply  | 
			
			 Universal power input  | 
		
| 
			 Software  | 
			
			 Windows software to record and export temperature-time data  | 
		
Optical Features
| 
			 Optical Access  | 
			
			 Reflection and transmission capability  | 
		
|---|---|
| 
			 Optical Windows  | 
			
			 Removable and exchangeable windows permit full-spectrum transparency  | 
		
| 
			 Minimum Objective Working Distance  | 
			
			 5mm  | 
		
| 
			 Minimum Condenser Working Distance  | 
			
			 11.5 mm  | 
		
| 
			 Top Window  | 
			
			 27 mm diameter  | 
		
| 
			 Top Viewing Angle  | 
			
			 ±65.0° from normal  | 
		
| 
			 Transmission Aperture  | 
			
			 2 mm diameter  | 
		
| 
			 Bottom Viewing Angle  | 
			
			 ±19° from normal  | 
		
| 
			 Window Defrost  | 
			
			 Integrated external window defrost  | 
		
Structural Features
| 
			 Sample Area  | 
			
			 28 mm x 30 mm  | 
		
|---|---|
| 
			 Chamber Height  | 
			
			 2.8 mm  | 
		
| 
			 Sample Positioning  | 
			
			 10 mm fine travel with Vernier XY dials for remote manipulation in closed chambers  | 
		
| 
			 Frame Cooling  | 
			
			 Integrated frame cooling with optional chiller system  | 
		
| 
			 Mounting  | 
			
			 Horizontal mounting capability  | 
		
| 
			 Frame Dimensions  | 
			
			 153 mm × 90 mm × 22 mm  | 
		
| 
			 Weight  | 
			
			 1000 g  | 
		
ACCESSORIES
| 
			 to keep the stage frame at room temperature  | 
		|
| 
			 enable sample cooling to as low as -190°C  | 
		|
| 
			 Relative humidity controller for sample chamber  | 
		|
| 
			 Mounting the stage to microscopes or optical table  | 
		|
| 
			 20mm longer working distance polarizing condersers  | 
		|
| 
			 C-mount digital camera with temperature overlay  | 
		|
| 
			 F2-HCS621GXY  | 
			
			 Optional electrical feedthroughs for this stage, 2X  | 
		
SIMILAR PRODUCTS
| 
			 PRODUCT  | 
			
			 Key differentiating features compare to HCS621GXY  | 
		
|---|---|
| 
			 400°C maximum temperature, but with vacuum capability, beside gas-tight  | 
		|
| 
			 Plate version, without aperture at the middle of the silver block. Better temperature uniformity, better for applications which requires only reflection, such as Raman  | 
		|
| 
			 400°C maximum temperature, but with large sample area, can accommadate 1"x3" microscope slide directly  | 
		|
| 
			 Besides standard IR windows, this stage has large cone angle for both condenser and objective lens  | 
		
Instec's HCS621GXY gas-tight stage is designed for applications where a wide temperature range is needed and control over the atmosphere is critical. This stage features a silver heating and cooling block, providing the user with exceptional temperature uniformity. The gas-tight configuration provides a sealed chamber for gas purge to avoid condensation or oxidation.
With the HCS621GXY stage, there is also an option for adding up to 8 elecric feedthroughs for sample connection and probing.