메뉴 건너뛰기

Thermal Properties Analyzer

Thermal conductivity (Lambda), Ash fusion, Thermal screening

Microscopic Hot/Cold Stage, Wafer chuck, Thermal plate, Thermal probe station

HCS421VXY Heating & Cooling Stage

HCS421VXY Heating & Cooling Stage

  • Microscopy and spectroscopy stage
  • -190°C - 400°C with liquid nitrogen cooling option
  • 28 mm × 30 mm sample area
  • XY sample positioning
  • Sealed chamber with vacuum capability

 

Description

Instec의 HCS421VXY Vacuum-tight stage는 넓은 온도 범위와 분위기 제어가 중요한 애플리케이션을 위해 설계되었습니다. 이 스테이지에는 silver heating 및 cooling block이 있어 탁월한 온도 균일성 (temperature uniformity)을 갖습니다. Vacuum-tight 구성은 수분과 산화로 부터 민감한 샘플을 보호하고 동결 건조와 같은 진공 공정을 연구하도록 가스 퍼지와 저압 배출이 가능합니다.

HCS421VXY 스테이지에는 샘플 체과 프로빙을 위한 최대 8 개의 elecric feedthrough 옵션를 추가할 수 있습니다.

 

Thermal Features

Temperature Control

mK2000 with programmable precision switching PID method

Thermal Block

Silver

Sample Thermal Cover

Removable Inner sample cover with additional window

Temperature Minimum

-190°C (with optional liquid N2 cooling)

Temperature Maximum

400°C

Temperature Sensor

100 Ω Platinum RTD

Maximum Heating Rate

+100°C per minute at 100°C

Maximum Cooling Rate

-60°C per minute at 100°C

Minimum Heating and Cooling Rate

±0.01°C per minute

Temperature Resolution

0.01°C

Temperature Stability

±0.05°C (above 25°C), ±0.1°C (below 25°C)

Power supply

Universal power input

Software

Windows software to record and export temperature-time data

 

Optical Features

Optical access

Reflection and transmission capability

Optical windows

Removable and exchangeable windows permit full-spectrum  transparency

Minimum Objective Working Distance

5 mm

Minimum Condenser Working Distance

11.5 mm

Top Window

27 mm diameter

Top Viewing Angle

±65° from normal

Transmission Aperture

2 mm diameter

Bottom Window

27 mm diameter

Bottom Viewing Angle

±19.0° from normal

 

Structural Features

Optical access

Reflection and transmission capability

Optical windows

Removable and exchangeable windows permit full-spectrum  transparency

Minimum Objective Working Distance

5 mm

Minimum Condenser Working Distance

11.5 mm

Top Window

27 mm diameter

Top Viewing Angle

±65° from normal

Transmission Aperture

2 mm diameter

Bottom Window

27 mm diameter

Bottom Viewing Angle

±19.0° from normal

HCS421VXY Heating & Cooling Stage

Instec's HCS421VXY vacuum-tight stage is designed for applications where a wide temperature range is needed and control over the atmosphere is critical. This stage features a silver heating and cooling block, providing the user with exceptional temperature uniformity. The vacuum-tight configuration can be both gas purged and evacuated to low pressures to protect sensitive samples from moisture and oxygen as well as to study vacuum processes such as freeze drying.
With the HCS421VXY stage, there is also an option for adding up to 8 elecric feedthroughs for sample connection and probing.


 

Instec, Inc. USA
share
Heating & Cooling Stage HCS302/HCS302XY Heating & Cooling Stage HCS302/HCS302XY Heating & Cooling Stage For optical microscopy and spectroscopy -60°C - 400°C Fi
댓글 0
13,600
Heating & Cooling Stage HCS402/HCS402XY Heating & Cooling Stage HCS402/HCS402XY Heating & Cooling Stage For optical thermal microscopy and spectroscopy -60°C ~
댓글 0
14,922
Heating & Cooling Stage HCS600-CUV Heating & Cooling Stage HCS600-CUV Heating & Cooling Stage Spectrophotometer thermal cell Fits standard 12.5 mm x 12.5
댓글 0
1,112
Heating & Cooling Stage HCS121GXY Heating & Cooling Stage HCS121GXY Heating & Cooling Stage Optical microscopy and spectroscopy -190°C - 100°C with liquid
댓글 0
1,073
Heating & Cooling Stage HCS121VXY Heating & Cooling Stage HCS121VXY Heating & Cooling Stage Microscopy and spectroscopy stage -190°C ~ 100°C with liquid n
댓글 0
1,060
Heating & Cooling Stage HCS321Gi Heating & Cooling Stage HCS321Gi Heating & Cooling Stage Compact stage for inverted microscope operation -190°C - 250°C
댓글 0
1,340
Heating & Cooling Stage HCS302GXY Heating & Cooling Stage HCS302GXY Heating & Cooling Stage For optical thermal microscopy and spectroscopy -190°C - 400°
댓글 0
1,075
Heating & Cooling Stage HCS421VXY Heating & Cooling Stage HCS421VXY Heating & Cooling Stage Microscopy and spectroscopy stage -190°C - 400°C with liquid n
댓글 0
1,203
Heating & Cooling Stage HCS621GXY Thermoelectric Stages HCS621GXY Thermoelectric Stages Optical microscopy and spectroscopy -190°C - 600°C with liquid nitro
댓글 0
1,108
« 1 2 3 4 5 6 7 8 »