SDTGA6000 Thermogravimetric Analyzer (Proximate Analyzer; 공업분석기)

Highlights

  1. Dual furnaces structure, the system consists of two parts, one for moisture and ash analysis, other for volatile matter analysis.
  2. For moisture and ash analysis, 19 samples can be loaded once + 1 blank sample position.
  3. For volatile matter analysis, vertical furnace structure is adopted with 26 positions. Upper part for high temperature volatile matter test while lower part for low temperature cooling and weighing, makes the test result more accurate and test efficiency greatly improved.
  4. Flexible software design, test procedure, analysis time, temperature etc. can be customized.
  5. Unique sample weighing mode, single sample weighing and batch sample weighing are both available, makes the operation convenient.
  6. After finishing the moisture and ash test, furnace cover will be opened automatically for furnace cooling down, thus to shorten the waiting time for next batch of test, makes the operation safe and efficient.
  7. LED displays on both furnaces to show real-time balance weight data, it makes the sample weighing more convenient.
  8. Automatic temperature calibration function is available.


Specification

Description

SDTGA6000 (include SDTGA6000A and SDTGA6000V)

Test index

Moisture, ash and volatile matter

Continuous test in batches

Yes

Standards

ISO 11722, ISO 1171, ISO 562, ASTM-D 5142-2009

Precision

0.02% RSD (1σ, 1g sample)

Furnace

 Dual furnaces, one for moisture and ash, one for volatile matter

Furnace temperature

Room temperature ~ 1000

Temperature control precision

± 2

Temperature resolution

0.1

Reproducibility

Ash: 0.30% (<15.00%); 0.50% (15.00~30.00%); 0.70% (>30.00%)
Volatile matter: 0.50% (<20.00%); 1.00% (20.00~40.00%); 1.50% (>40.00%)

Cooling time required for batches of test

No

Furnace Cooling (forced air/N2)

950 to 500°C <30 min

Balance Resolution

0.0001g

Sample introduction and taking

Automatic

Max. Samples

19 samples + 1 blank sample position (Moisture & Ash)

26 samples + 1 blank sample position (Volatile matter)

Quantity of sample / test time:

Full indexes for 19 samples< 120 min (Quick method)

Sample weight

0.5 up to 5g

Max. power

4 kW for moisture/ash testing;
2.5 kW for volatile matter testing

Interface:

RS232

Furnace Heating

Resistance Wound

Temperature Calibration

Standard thermocouple

Temp. control precision

± 2 for moisture
± 5
 for ash, volatile matter

Gas Flow Rate

Moisture:Nitrogen or Air 2~4(Furnace Volume /min)
Volatile matter:Nitrogen 2~4(Furnace Volume /min)

Power requirement

220VAC ±10%50 / 60Hz

Gas requirement

Nitrogen / Oxygen / Compressed Air

Gas Pressure

Air 5 to 6 bar (75 to 90 psi)

Minimum Gas Purity

Air/Nitrogen/Oxygen 99.5%; dry, oil-free

Sample weighing

Under normal temp.

Test Temperature

  • Moisture 105
  • Ash 815
  • Volatile matter 920950 

Can be customized

Humidity

<80%

Dimensions

Moisture & ash analyzer: 550 x 590 x530mm      
Volatile matter analyzer: 550 x 650 x 815mm

Weight

Moisture & Ash analyzer: 70kg      
Volatile matter analyzer: 95kg

Operational Control

Windows7/ Windows10 on external PC

Advance Calculation

Yes

Analysis Report

Yes

Statistics Report

Yes

System Monitor

Yes

 

SDTGA6000 Thermogravimetric Analyzer (Proximate Analyzer)

SDTGA6000 can be used to determine the moisture, ash and volatile matter as well as calculation of fixed carbon and calorific value in coal, coke, calcined petrol coke and other solid biomass fuel.

Dual Furnaces,stable performance, accurate test result.
19 samples+1 blank sample for moisture & ash; 25 samples+1 blank sample for volatile matter


 

share