메뉴 건너뛰기

Element Analyzers

CHNS Analyzer, XRF, AES, OES, Spark-OES, AAS, AFS, ADX

AF-630A/640A Atomic Fluorescence Spectrometer, AFS

  • Ultra trace level (ng/mL) determination of As, Sb, Bi, Zn, Cd, Hg, Ge, Sn, Pb, Se and Te.
  • Double channels / triple channels, two elements / three elements determination simultaneously.
  • Upgradable to atomic fluorescence speciation analyzer.
  • Especially suitable for geologic samples, simultaneous analysis of As, Sb & Bi (AF-630A).  

 

Features

 Light Source System

  •  Single-cathode or double-cathode hollow cathode lamp can be used as the light source.  
  • Pulse power supply mode for higher stability and lower drift.
  •  Main current and auxiliary current of double-cathode HCL are automatically matched by PC.

 Optical System

  •  Short focal length, non-dispersive, and light close optical system

 Advanced gas-liquid separator, with higher signal-to-noise ratio

  •  Comparable performance with Nafion drier
  •  Anti-foaming design, especially suitable for ion pair separation method
  • Waste liquid auto drain design, no peristaltic pump is necessary

 Low temperature atomization technique

  •  Argon-hydrogen flame auto ignition
  •  Stable temperature control system
  •  Very high stability atomization efficiency

 Long life (3 years) and high efficiency (70%) active and recycling mercury trap

 Powerful function and upgrading capability

  •  Adding PDI-10 UV digestion device and work station, and coupled with chromatographs realizes speciation analysis of As, Hg, and Se.
  •  Adding WM-10 Ultra-trace Hg determination device to determine directly the ultra-trace Hg in water samples of surface water, sea water, tap water and source water, etc.
  •  Adding VM-10 Gaseous Hg determination device to determine directly the ultra-trace Hg in gas sample of air, natural gas, laboratory and working environment, etc.
  •  Two kinds of autosamplers available for fully automatic operation.

 

Analytical Results of GSD(sediment) and GSS(soil) Certified Reference Materials (CRM) by AF-630A

CRM
 
As (μg/g)
Sb (μg/g)
B (μg/g)
Results
Average
Certified result
Results
Average
Certified result
Results
Average
Certified result
GSD-2
GSD-2-1
5.53
5.6
5.3~7.1
0.42
0.41
0.29~0.63
1.62
1.63
1.47~1.81
GSD-2-2
5.57
0.41
1.66
GSD-2-3
5.82
0.41
1.59
GSD-3
GSD-3-1
15.11
15.4
14.6~20.6
4.75
4.83
4.6~6.2
0.70
0.70
0.65~0.93
GSD-3-2
15.56
4.82
0.72
GSD-3-3
15.44
4.93
0.69
GSD-4
GSD-4-1
18.83
18.7
17.1~22.3
1.70
1.83
1.57~2.11
0.54
0.54
0.49~0.79
GSD-4-2
19.00
1.87
0.56
GSD-4-3
18.22
1.93
0.51
GSD-6
GSD-6-1
12.42
12.6
12.1~15.1
1.06
1.06
0.92~1.58
4.81
4.83
4.4~5.6
GSD-6-2
12.44
1.05
4.92
GSD-6-3
12.93
1.08
4.76
GSS-1
GSS-1-1
34.59
34.7
31.8~35.2
0.84
0.85
0.75~0.99
1.18
1.18
1.11~1.23
GSS-1-2
34.91
0.87
1.15
GSS-1-3
34.66
0.84
1.20
AF-630A/640A Atomic Fluorescence Spectrometer, AFS 


 

share
« 1 2 3 4 »