Technical parameter
Model No. |
XRD-3000 |
Rated power |
3kW |
Tube voltage |
10-60kV |
Tube current |
5-80mA |
X-ray tube |
Glass tube, ceramic tube, ripple ceramic tube: Cu, Fe, Co, Cr, Mo etc, Power 2kW |
Focus size |
1 x 10mm or 0.4 x14mm or 2 x 12mm |
Stability |
≤0.01% |
Goniometer structure |
Horizontal (θ -2θ) |
Radius of diffraction |
185mm |
Scanning range |
0-164 |
Scanning speed |
0.0012° – 70° min |
Max. revolving speed |
100°/min |
Scanning fashion |
θ -2θ linkage, θ 、2θ single action; continuous or stepping scanning |
Angle repeatable accuracy |
1/1000° |
Minimal stepping angle |
1/1000° |
Detector |
Proportional counters (PC) or scintillation counters (SC) |
Maximal counting rate of linearity |
5x105 CPS (with the compensate function of drop out counting) |
Energy resolution ratio |
≤25% (PC), ≤50% (SC) |
Counting fashion |
Differential coefficient or integral, PHA automatically, dead time regulate |
Stability of system measure |
≤0.01% |
Scattered rays dose |
≤1μ Sv/h (without X-ray protective device) |
Instrument integrative stability |
≤0.5% |
Dimension |
1100 x 850 x1750mm |
XRD-3000 X-Ray Diffractometer Components
X-Ray High Voltage Generator
- 1505 High Voltage Transformer
- AL-75kV High Voltage Cable
- 9850 Control panel
- 9820 High voltage control unit
- 9830 Control gate
- 9810 System Case
- 9840 Main power cable
- X-ray tube 2kW Cu, Focus size 1×10mm²
- 3306 Tube holder
- 9924 X-ray Protective cover
Angle Measuring System
- 3501 Goniometer
- Goniometer layer board
- Powder sample holder
- Powder sample plate with blind Holes
- Powder sample plate with through holes
- Micronutrient powder sample board
- Zero setting sample piece, double-knife edge slit
- Standard ruler, watch oil
- Filter Ni
- Slit
Recording and Controlling Unit
- 2013 Recording and controlling units
- CH132 Scintillation counter
- Counter cable
- Stepping motor cable
- Interface cable
Circulating Water Cooling System
- ZFB-3000 Cooling device
- 9509 Power cable
- Water pipe 6 meters
- Water relay cable
Computer & System Control Program and Applicable Software
- Data collecting and processing software
- Data analysis and processing software
- Application software
- Diffraction data card stock
Technical Material
- XRD-3000 X-ray diffractometer user manual
- ZFB-3000 Cooling device user manual
Spare Parts
- Ring rubber blanket
- Fuse 2A, 3A, 6A
X-Ray Diffractometer Property and Technical Parameter
High pressure generator(Adopting imported PLC control technology)
- Rated Power:3kW
- Tube Voltage:10~60kV It is automatically controlled by computer terminal(1kV/step)
- Tube Current:5~80mA It is automatically controlled by computer terminal(1mA/step)
- Tube Voltage and Current Stability≤0.01%
- Protection of over voltage, over current, over power, and low water level
- X-Ray Tube:Cu target、Focal point 1×10mm2、Power 2.0kW;
- Optical shutter switch is automatically controlled by computer terminal
- Unibody structure cooling device, Cooling device is unibody structure, and the automatic temperature control system can indicate the water temperature of X-ray tube.
It adopts PLC control technology, has high degree of automation, low failure rate, strong anti-jamming capability, excellent system stability and long using life.
Goniometer and Control (Horizontal type):
Horizontal Type θ -2θ, diffraction circle radius 185mm; Rotation of goniometer is controlled by stepping motor (forward or reverse, forward scan), drive mode (move individually or jointly ), scanning mode(continuous, stepping), scanning speed, it can do angle-auto correction, detect losing step and avoid lost motion;
- Minimum Step Angle: 0.001°
- Continues Scan Speed: 0.0012°-70°min
- Step scanning step width angle: 0.005~165°
- 2θ Angle measurement range:≤0.005°
- 2θ Angle measurement range:0--164°
- Goniometer 2θ angle uni-directional Repeatability 0.001°
Recording and Controlling Unit and Detector:
- Closed scintillation counter
- Auto differential and integral conversion
- Base line and channel width: 0%~99%
- Continuous adjustable high voltage of detector : 0~2000V
- High voltage stability of detector: ≤0.01%
- Optional X-ray tube target material: Cr、Fe、Co、Cu、Mo
- Energy Spectrum Analysis (Cu,Kα CuKa Curve): ≤25% (PC), ≤50% (SC)
Overall Stability
System overall stability ≤0.3%
Outline Dimension
Outline Dimension:1100×850×1750mm