메뉴 건너뛰기

Calorimeter

Bomb Calorimeter, Micro Reaction Calorimeter
Isothermal Titration Calorimeter, Cement Calorimeter, Bio Calorimeter
IBC Isothermal Battery Calorimeter

SDACM4000 Bomb Calorimeter

SDACM4000은 25분 이내에 석탄, 코크스, 석유 오일, 시멘트 흑분 (cement black meal), 바이오매스 연료 및 건축 자재와 같은 고체 및 액체 가연성 물질, 다양한 식품의 발열량을 결정하는 데 사용할 수 있습니다.


- Analysis time is about 15~25 min;
- Conforms to ISO and ASTM international standard

 

Features:

· High automation

  •   Automatic oxygen filler equipped, oxygen filling by one press.
  •   Automatic sample ignition. 
  •   Automatic temperature rise measurement and result calculation 


· High temperature resolution

  • Temperature control utilizes a PT1000 Platinum resistance probe for temperature resolution to the nearest 0.0001k to improve the test precision.
  • Durable bombs need hydrostatic pressure test only once a year. 
  • With PCI interface, several calorimeters can be controlled by a single PC.
  • onnected with balance and network by standard interface RS232, real time data can be transmitted through internal network. 
  • Easy-to-use Windows-based software, easy data handling.
  • Vertical Type, Jacket Water: ≥40kgs to ensure the stability of jacket water temperature.

 

Applications
Sundy calorimeters can be used to determine the calorific value of coal, coke, petroleum, cement black meal, solid biomass fuels and other combustibles. 

Conformance with Standards
ASTM D5865-2010 Standard Test Method for Gross Calorific Value of Coal and Coke
ISO1928 Solid Mineral Fuels : Determination of gross calorific value by the bomb calorimetric method and calculation of net calorific value


 

 

 

Specifications: 

Description

SDACM4000

Analysis Time

15min-25min

Temperature Resolution

0.0001K

Precision(RSD)

≤0.15%

Heat Capacity Stability

≤0.25% within three months

System Structure

Vertical

Conformance with Standard

ASTM D5865, ASTM D240, ASTM D4809, ASTM E711, ASTM D5468, AS 1038.5,BS EN 15400, BIS1350,ISO 1928, ISO 9831,ISO18125,GB/T 213,GB/T 30727               

Test per Hour

2~4

Bomb volume

282ml

Calorimeter Type

Isoperibol

Oxygen Filling

Semi-automatic

Bomb Washing

Manual

Max.Bomb pressure

20Mp

Bomb Identity

No

Gas Requirement

99.5% Oxygen

Water Requirement

Distilled  Water

Energy Measurement Range

0~50000J

Bucket Filling

Automatic

Constant Volumetric Tank with Temp Control Device

No

Independent Bucket and Jacket Water System

No

Stirring Method

Blade

Power Inverter

No

Reproducibility based on analysis of 1g Benzoic Acid

0.15%

Average Temperature Increase

2℃

Temperature Measurement

PT1000

Working Temperatures

≦32℃

Cooling method

Automatic by water circulation

Network

Yes

Power

220V(-15% +10%)50/60Hz

Max Power

0.5kW

Dimension

Main body: 600*417*908

Weight

106kg

Advance Calculation

No

Analysis Report

Yes

Statistics Report

Yes

System Monitor

Yes

SDACM4000 Bomb Calorimeter


 

share