HCS402/HCS402XY Heating & Cooling Stage
- 
	
For optical thermal microscopy and spectroscopy
 - 
	
-60°C ~ 400°C temperature range
 - 
	
Dual top-bottom heating for reduced vertical temperature gradients.
 - 
	
Large chamber to fit standard 25 mm × 75 mm microscope slides, liquid crystal cell holders, and electro-optical devices
 - 
	
Sample side-loading and removeable XY sample positioning
 
Description
Instec's HCS402/HCS402XY microscope hot and cold stage features a dual heater design which virtually eliminates vertical temperature gradients in the sample chamber. This makes the HCS402/HCS402XY temperature controlled environment an ideal choice for thicker samples or when the best available temperature uniformity is necessary. Top and bottom dual pane windows in the HCS402/HCS402XY stage are removeable and exchangeable to meet a range of spectroscopic needs. The stage can be mounted vertically for applications requiring horizontal beam access to the sample chamber. The interior of the HCS402/HCS402XY is large enough to accommodate a variety of samples, including electro-optic devices and standard 25 mm x 75 mm microscope slides.
The integrated top cover heater provides supreme above-ambient temperature stability and uniformiy - a must have for precision experiments!
Thermal Features
| 
			 Temperature Control  | 
			
			 mK2000 with programmable precision switching PID method  | 
		
|---|---|
| 
			 Thermal Block  | 
			
			 Clear anodized aluminum  | 
		
| 
			 Sample Thermal Cover  | 
			
			 Removable Inner sample cover with additional window  | 
		
| 
			 Temperature Minimum  | 
			
			 -60°C (with optional liquid N2 cooling)  | 
		
| 
			 Temperature Maximum  | 
			
			 400°C  | 
		
| 
			 Temperature Sensor  | 
			
			 100 Ω Platinum RTD  | 
		
| 
			 Maximum Heating Rate  | 
			
			 +150°C per minute at 100°C  | 
		
| 
			 Maximum Cooling Rate  | 
			
			 -40°C per minute at 100°C  | 
		
| 
			 Minimum Heating and Cooling Rate  | 
			
			 ±0.01°C per minute  | 
		
| 
			 Temperature Resolution  | 
			
			 0.01°C  | 
		
| 
			 Temperature Stability  | 
			
			 ±0.05°C (above 5°C), ±0.1°C (below 25°C)  | 
		
| 
			 Power Supply  | 
			
			 Universal power input  | 
		
| 
			 Software  | 
			
			 Windows software to record and export temperature-time data  | 
		
Optical Features
| 
			 Optical Access  | 
			
			 Reflection and transmission capability  | 
		
|---|---|
| 
			 Optical Windows  | 
			
			 Removable and exchangeable windows permit full-spectrum transparency  | 
		
| 
			 Minimum Objective Working Distance  | 
			
			 7.4 mm  | 
		
| 
			 Minimum Condenser Working Distance  | 
			
			 10.3 mm  | 
		
| 
			 Top Window  | 
			
			 27 mm diameter (10 mm inner cover)  | 
		
| 
			 Top Viewing Angle  | 
			
			 ±47° from normal  | 
		
| 
			 Transmission Aperture  | 
			
			 2 mm diameter (5 and 8 mm options)  | 
		
| 
			 Bottom Viewing Angle  | 
			
			 ±45° from normal  | 
		
| 
			 Window Defrost  | 
			
			 Integrated external window defrost  | 
		
Structural Features
| 
			 Sample Area  | 
			
			 38 mm x 50 mm  | 
		
|---|---|
| 
			 Chamber Height  | 
			
			 2.1 mm with removeable inner cover Additional height with optional spacers  | 
		
| 
			 Sample Loading  | 
			
			 Quick sample handling with side loading/unloading holder  | 
		
| 
			 Sample Positioning  | 
			
			 10 mm fine travel with Vernier XY dials for remote manipulation in closed chambers  | 
		
| 
			 Frame Cooling  | 
			
			 Integrated frame cooling with optional chiller system  | 
		
| 
			 Mounting  | 
			
			 Horizontal and vertical mounting capability  | 
		
| 
			 Frame Dimensions  | 
			
			 116.84 mm x 111.76 mm x 23.11 mm  | 
		
| 
			 Weight  | 
			
			 780 g  | 
		
Instec's HCS402/HCS402XY microscope hot and cold stage features a dual heater design which virtually eliminates vertical temperature gradients in the sample chamber. This makes the HCS402/HCS402XY temperature controlled environment an ideal choice for thicker samples or when the best available temperature uniformity is necessary. Top and bottom dual pane windows in the HCS402/HCS402XY stage are removeable and exchangeable to meet a range of spectroscopic needs. The stage can be mounted vertically for applications requiring horizontal beam access to the sample chamber. The interior of the HCS402/HCS402XY is large enough to accommodate a variety of samples, including electro-optic devices and standard 25 mm x 75 mm microscope slides.
The integrated top cover heater provides supreme above-ambient temperature stability and uniformiy - a must have for precision experiments!