메뉴 건너뛰기

Thermal Properties Analyzer

Thermal conductivity (Lambda), Ash fusion, Thermal screening

Microscopic Hot/Cold Stage, Wafer chuck, Thermal plate, Thermal probe station

HCS121VXY Heating & Cooling Stage

HCS121VXY Heating & Cooling Stage


  • Microscopy and spectroscopy stage
  • -190°C ~ 100°C with liquid nitrogen cooling option
  • 28 mm × 30 mm sample area
  • XY sample positioning
  • Sealed chamber with vacuum capability

 

Thermal Features

Temperature Control

mK2000 with programmable precision switching PID method

Thermal Block

Silver

Sample Thermal Cover

Removable Inner sample cover with additional window

Temperature Minimum

-190°C (with optional liquid N2 cooling)

Temperature Maximum

100°C

Temperature Sensor

100 Ω Platinum RTD

Maximum Heating Rate

+150°C per minute at 37°C

Maximum Cooling Rate

-60°C per minute at 100°C

Minimum Heating and Cooling Rate

±0.01°C per minute

Temperature Resolution

0.01°C

Temperature Stability

±0.05°C (above 25°C), ±0.1°C (below 25°C)

Power supply

Universal power input

Software

Windows software to record and export temperature-time data

 

Optical Features

Temperature Control

mK2000 with programmable precision switching PID method

Thermal Block

Silver

Sample Thermal Cover

Removable Inner sample cover with additional window

Temperature Minimum

-190°C (with optional liquid N2 cooling)

Temperature Maximum

100°C

Temperature Sensor

100 Ω Platinum RTD

Maximum Heating Rate

+150°C per minute at 37°C

Maximum Cooling Rate

-60°C per minute at 100°C

Minimum Heating and Cooling Rate

±0.01°C per minute

Temperature Resolution

0.01°C

Temperature Stability

±0.05°C (>25°C), ±0.1°C (<25°C)

Power supply

Universal power input

Software

Windows software to record and export temperature-time data

 

Structural Features

Sample Area

28 mm x 30 mm

Chamber Height

2.8 mm

Sample Access

Side-loading outer cover for quick sample access without  refocusing instruments

Sample Positioning

10 mm fine travel with Vernier XY dials for remote manipulation  in sealed chambers

Atmosphere Control

Sealed chamber with vacuum capability to control humidity,  condensation, and oxidation

Frame Cooling

Integrated frame cooling via hose barb ports with optional  chiller system

Mounting

Horizontal and vertical mounting capability

Frame Dimensions

153mm x 90 mm x 22 mm

Weight

1350 g light-weight aluminum body

 


 

Instec, Inc. USA
share
Heating & Cooling Stage HCS302/HCS302XY Heating & Cooling Stage HCS302/HCS302XY Heating & Cooling Stage For optical microscopy and spectroscopy -60°C - 400°C Fi
댓글 0
13,599
Heating & Cooling Stage HCS402/HCS402XY Heating & Cooling Stage HCS402/HCS402XY Heating & Cooling Stage For optical thermal microscopy and spectroscopy -60°C ~
댓글 0
14,922
Heating & Cooling Stage HCS600-CUV Heating & Cooling Stage HCS600-CUV Heating & Cooling Stage Spectrophotometer thermal cell Fits standard 12.5 mm x 12.5
댓글 0
1,112
Heating & Cooling Stage HCS121GXY Heating & Cooling Stage HCS121GXY Heating & Cooling Stage Optical microscopy and spectroscopy -190°C - 100°C with liquid
댓글 0
1,073
Heating & Cooling Stage HCS121VXY Heating & Cooling Stage HCS121VXY Heating & Cooling Stage Microscopy and spectroscopy stage -190°C ~ 100°C with liquid n
댓글 0
1,059
Heating & Cooling Stage HCS321Gi Heating & Cooling Stage HCS321Gi Heating & Cooling Stage Compact stage for inverted microscope operation -190°C - 250°C
댓글 0
1,339
Heating & Cooling Stage HCS302GXY Heating & Cooling Stage HCS302GXY Heating & Cooling Stage For optical thermal microscopy and spectroscopy -190°C - 400°
댓글 0
1,073
Heating & Cooling Stage HCS421VXY Heating & Cooling Stage HCS421VXY Heating & Cooling Stage Microscopy and spectroscopy stage -190°C - 400°C with liquid n
댓글 0
1,202
« 1 2 3 »
« 1 / 3 »