HCS621GXY Thermoelectric Stages
-
Optical microscopy and spectroscopy
-
-190°C - 600°C with liquid nitrogen cooling option
-
28 mm × 30 mm sample area
-
XY sample positioning
-
Sealed chamber with gas purging capability
Description
Instec의 HCS621GXY gas-tight stage는 넓은 온도 범위와 분위기 제어가 중요한 애플리케이션을 위해 설계되었습니다. 이 스테이지에는 silver heating 및 cooling block이 있어 온도 균일성(temperature uniformity)이 뛰어납니다. 응축 (condensation) 또는 산화(oxidation)를 방지하도록 가스 퍼지를 위한 씰드 챔버를 제공합니다.
HCS621GXY 스테이지에는 샘플 체결 및 프로빙이 가능하도록 최대 8 개의 elecric feedthrough 옵션을 추가할 수 있습니다.
Thermal Features
Temperature Control |
mK2000 with programmable precision switching PID method |
---|---|
Thermal Block |
Silver for superior thermal uniformity |
Temperature Minimum |
-190°C (with optional liquid N2 cooling) |
Temperature Maximum |
600°C |
Temperature Sensor |
100 Ω Platinum RTD |
Maximum Heating Rate |
+150°C per minute at 100°C |
Maximum Cooling Rate |
-50°C per minute at 100°C |
Minimum Heating and Cooling Rate |
±0.01°C per minute |
Temperature Resolution |
0.01°C |
Temperature Stability |
±0.05°C (above 25°C), ±0.1°C (below 25°C) |
Power Supply |
Universal power input |
Software |
Windows software to record and export temperature-time data |
Optical Features
Optical Access |
Reflection and transmission capability |
---|---|
Optical Windows |
Removable and exchangeable windows permit full-spectrum transparency |
Minimum Objective Working Distance |
5mm |
Minimum Condenser Working Distance |
11.5 mm |
Top Window |
27 mm diameter |
Top Viewing Angle |
±65.0° from normal |
Transmission Aperture |
2 mm diameter |
Bottom Viewing Angle |
±19° from normal |
Window Defrost |
Integrated external window defrost |
Structural Features
Sample Area |
28 mm x 30 mm |
---|---|
Chamber Height |
2.8 mm |
Sample Positioning |
10 mm fine travel with Vernier XY dials for remote manipulation in closed chambers |
Frame Cooling |
Integrated frame cooling with optional chiller system |
Mounting |
Horizontal mounting capability |
Frame Dimensions |
153 mm × 90 mm × 22 mm |
Weight |
1000 g |
ACCESSORIES
to keep the stage frame at room temperature |
|
enable sample cooling to as low as -190°C |
|
Relative humidity controller for sample chamber |
|
Mounting the stage to microscopes or optical table |
|
20mm longer working distance polarizing condersers |
|
C-mount digital camera with temperature overlay |
|
F2-HCS621GXY |
Optional electrical feedthroughs for this stage, 2X |
SIMILAR PRODUCTS
PRODUCT |
Key differentiating features compare to HCS621GXY |
---|---|
400°C maximum temperature, but with vacuum capability, beside gas-tight |
|
Plate version, without aperture at the middle of the silver block. Better temperature uniformity, better for applications which requires only reflection, such as Raman |
|
400°C maximum temperature, but with large sample area, can accommadate 1"x3" microscope slide directly |
|
Besides standard IR windows, this stage has large cone angle for both condenser and objective lens |