​​​​​​​QCM Quartz Crystal Monitor

QCM Quartz Crystal Monitor

QCM 40-200 Quartz Crystal Monitor on DN40CF (O.D. 2.75") flange with 200 mm linear travel

 

  • Quartz crystal microbalance for thin-film measurements
  • Compatible with most oscillator devices
  • Mounting Flange DN40CF (2.75” O.D.), rotatable
  • Linear travel 150 mm, 200 mm or 250 mm  
  • Bakeable up to 250°C

Introduction

This standard Quartz Crystal Microbalance can be used for in situ flux calibration in many MBE applications. Due to the linear travel it is possible to move the quartz directly under the substrate for accurate rate measurements.

The main component is a gold-plated piezo crystal which oscillates with its natural frequency. If material hits the quartz surface and sticks there the mass of the quartz will change. The change of mass results in a change of the natural frequency which will be detected.

The QCM instrument enables the measurement of thickness changes in the range of sub atom layers, i.e. < 1 nm. To overcome disturbing temperature effects the QCM is water-cooled.

 

Application

Typical applications for the QCM Quartz Crystal Microbalance are:

  •   Flux calibration of effusion cells with regard to the cell temperature

  •   Uniformity measurements using the linear travel to measure the flux rate at different positions

  •   In-situ thickness control during the MBE process

 

Technical Data

Mounting flange

DN40CF (O.D. 2.75")

In vacuum lenght L

100...500 mm, others on request

Linear travel T

150, 200, 250 mm, others on request

Bakeout temperature

up to 250 °C

Oscillator connector

BNC

Cooling water

2 x Swagelok Ø 8 mm

Measurement range

depends on oscillator device

 

Dimensions

E represents the internal length of the linear travel. T represents the available linear travel.
L is defined for the situation of fully retracted linear shift as pictured in the drawing.

The length E varies with the maximum travel T. Please choose from the following table:

Variable T

Variable E

150

105

200

120

250

135

 

Specific data

For general information on CF mounting flanges see Flange and Gasketdimensions .

Product

CF flange

Linear travel

UHV dimensions***
[mm]

 

 

[mm]

[mm] / [mm]

QCM

40 -

150 -

LxxxD35

QCM

40 -

200 -

LxxxD35

QCM

40 -

250 -

LxxxD35

 

 

 

share
Equipment CS Cooling Shrouds CS Cooling Shrouds CS 100-63-S, water cooling shroud with integrated shutter on a DN100CF (O.D. 6")
댓글 0
26
Equipment Manipulator Control Unit PMCU Manipulator Control Unit PMCU Programmable Manipulator Control Unit MCU Precise control of substrate
댓글 0
19
Equipment Motorized Valve Control Unit MVCU Motorized Valve Control Unit MVCU The Motorized Valve Control Unit (MVCU) provides the power and con
댓글 0
22
Equipment Power Supply PS Power Supply PS The Power Supplies PS and PID temperature controllers provide precise temperature co
댓글 0
23
Equipment CA Cables and Connectors CA Cables and Connectors Power cables, cross-sections 2 x 2.5 / 25 / 16 mm², different lengths Solu
댓글 0
24
Equipment MCU Manipulator Control Unit MCU Manipulator Control Unit Manipulator control unit MCU Precise substrate rotation control Brushle
댓글 0
23
Equipment Multi-position Shutter Control Unit MSCU Multi-position Shutter Control Unit MSCU The MSCU is the power supply and controller for multi-posit
댓글 0
23
« 1 2 3 4 5 6 »
« 1 / 6 »
문의
하기